Sale!

Preen AFC-33005

Original price was: $4,874.68.Current price is: $3,564.73.

54 in stock

SKU: AFC33005 Category:

Description

  • AC power source capable of simulating standard or abnormal voltage and frequency status
  • Allows users to simulate all sorts of utility grid voltage and frequency for export product testing or operation of imported equipment
  • Suitable for Certified Bureau along with production of home appliances, electrical electronics, medical equipment, and lighting
  • Instrument can be applied as isolation between device under test (DUT) and grid to reduce amount of interference from each side
  • Lower total harmonic distortion (THD) allows for cleaner waveforms and ensures more accurate test results
  • Comprehensive protections include overvoltage, overcurrent, overload, input undervoltage, and overheat
  • Corresponding fault code will show and buzzer will alarm once protection mode is activated
  • Emergency stop button allows for manual stopping of output by user
  • 4 groups of LEDs display output voltage, current, and frequency
  • Built-in hotkey function allows for quick memory recall and easy voltage/frequency setting
  • Large touchscreen allows for precise adjustments of parameters and easy remote control
  • Display provides real-time monitoring of voltage, current, and active power
  • Effortless switching between phase-to-phase and phase-to-neutral displays with single click
  • Modularized inverter is compact, easy to maintain, and offers high power density
  • CE and RoHS certification with high performance in safety and electromagnetic compatibility
  • CE certified, compliant with EMC and LVD standards

Specifications

  • Input Phase: 1⌀ 2W+G
  • Input Voltage: 220VAC ±15%
  • Input Frequency: 47 to 63 Hz
  • Output Power: 3 kVA
  • Output Phase: 1⌀ 2W+G
  • Output Voltage Ranges: 0 to 155V (LOW), 0 to 310V (HIGH)
  • Output Frequency Range: 45 to 65 Hz
  • Maximum Output Current (RMS): 25A (LOW), 12.5A (HIGH)
  • Measurement Voltage Range: 0 to 310V
  • Measurement Frequency Range: 45 to 400 Hz
  • Measurement Current Range (RMS): 0 to 250A
  • Measurement Power Range: 0 to 3 kW
  • Touchscreen Size: 7 in.
  • Interfaces: RS-232/RS-485

Specifications

  • Input Phase: 3⌀ 3W+G
  • Input Voltage: 380VAC ±15%
  • Input Frequency: 47 to 63 Hz
  • Maximum Input Current: 11A
  • Output Power: 5 kVA
  • Output Phase: 3⌀ 4W+G
  • Output Voltage Ranges: 0 to 155V (LOW), 0 to 310V (HIGH)
  • Output Frequency Range: 45 to 65 Hz
  • Maximum Output Current (RMS): 13.9A (LOW), 6.9A (HIGH)
  • Measurement Voltage Range: 0 to 310V
  • Measurement Frequency Range: 45 to 400 Hz
  • Measurement Current Range (RMS): 0 to 13.9A
  • Measurement Power Range: 0 to 5 kW
  • Touchscreen Size: 7 in.
  • Interfaces: RS-232/RS-485